3daycrown.com
3daycrown.com
Facebook Icon
Facebook Icon
RX Form Icon
RX Form Icon
Turn-Time Calculator Icon
Turn-Time Calculator Icon
Print Shipping label Icon
Print Shipping label Icon
Dentures

In-lab turn-time - Set-up for try-in: 3 Days

In-lab turn-time - Process & Finish: 3 Days

We understand that dentures are a major investment for any patient. Our expert denture technicians create functional and highly esthetic dentures to fit any patient’s budget. Using a variety of base materials and teeth, our denture department stands ready to make your patients smile again.

Send A Case

Removables

Indications

Indicated for use as a removable full or partial denture in place of traditional acrylic or saddles on cast-metal partial. A tissue borne appliance when not used with cast-metal partials; rest seats are not recommended. Can also be used in combination with metal framework or precision attachment cases.

Contraindications

Should not be used with patients with poor oral hygiene, very short or heavily worn lower anteriors, over a closed vertical dimension or protruding tori. When there is minimal undercut on abutment teeth, metal clasp will be recommended. Cannot be relined chairside; appliance needs to be returned to the lab for rebase.

Preparation

Start with an accurate bite registration and void-free impression using a custom tray.

Cementation

None neccessary.

Codes

  • D5110 Complete upper
  • D5120 Complete lower
  • D5130 Immediate upper
  • D5860 Overdenture complete
Flexible Partials

Standard in-lab turn-time: 7 Days

Our Valplast® flexible partials offer the perfect blend of comfort and function. Lightweight and flexible to adapt to patients’ mouths as they speak and eat, Valplast bases are durable, odor-resistant and hypoallergenic.

Send A Case

Removables

Indications

Valplast® and similar flexible products are recommended for use as removable partial dentures in place of traditional acrylic saddles on cast metal partials, flippers or stayplates. Valplast and similar flexible products are tissue borne appliances when not used with cast metal partials. Rest seats in are not recommended. Valplast and our other flexible products eliminate the need for invasive procedures.

Contraindications

Valplast and our other flexible products should not be used with patients with poor oral hygiene, very short or heavily worn lower anteriors, over a closed vertical dimension or protruding tori. When there is minimal undercut on abutment teeth, metal clasp will be recommended. Our flexible products cannot be relined chairside; appliance needs to be returned to the lab for rebase.

Preparation

Start with an accurate bite registration and void-free impression using a custom tray.

Cementation

None necessary.

Tech Notes

Valplast Insertion Techniques

After unpacking the case and immediately prior to insertion in the patient’s mouth, immerse the case in very hot tap water. Leave the case in the water for about one minute. Remove the case from the water and allow it to cool just to the point where the patient will tolerate it. Gently insert the appliance into the mouth.

The hot water treatment permits a smooth initial insertion and a good adaptation with the natural tissues in the mouth. If the patient senses any discomfort because of the tightness of a clasp, the clasp may be loosened slightly by immersing that area of the partial in hot water and bending the clasp outward. If a clasp requires tightening, the clasp area may be immersed in hot water and bent inward to tighten.

If any reduction is needed due to persistent irritation, the resin must be handled differently than acrylic. It is essential to use a fairly coarse grinding wheel or a parallel cut steel bur (vulcanite bur) for overall reduction. The resin will melt if there is prolonged contact with a bur or wheel; therefore it is essential to move the instrument over the surface continuously.

Minor Relief can be made with a rubber wheel or vulcanite bur. If there are any threads remaining, these can be removed with a sharp blade. Any roughness on the surface can be smoothed with a brown rubber wheel.

Repairing or rebasing can only be done at Arcari. We require the doctor to use a wash material under partial, then do a full pick-up impression and send in with an opposing model and a bite. Re-basing is pressure induced.

Codes

  • D5211 Upper
  • D5212 Lower
Acrylic Partials

Standard in-lab turn time: 3 Days

Economic yet durable, DIL’s acrylic partials are poured with a rigid base, to maximize durability and esthetics. Crafted for perfect stability and retention to provide patients with functional, esthetic dentures, our acrylics allow for easy chairside modifications and addition of teeth at a later date.

Send A Case

Removables

Indications

Indicated for conventional partial denture applications. Also indicated for esthetic clasp partial denture applications. Indicated for combination crowns with attachments and partial denture applications.

Cast Partials

Standard in-lab turn-time: 7 Days

We rely on Vitallium 2000’s established track record for our cast partials. As adjustable chairside as gold, it’s flexible and durable enough to be nearly unbreakable under normal conditions.

Send A Case

Removables